Mechanical & Structural Design
Parameter Engineering Detail
Material Selection All wetted components (pump casing, nozzles, piping) constructed from 316L stainless steel, duplex stainless steel, or ceramic to resist chloride-induced corrosion, scaling, and abrasion from high TDS brine. Structural frames galvanized or coated with epoxy/polyurethane paints for UV, chemical, and dust resistance.
Pump Design High-pressure plunger or multistage centrifugal pump designed for continuous duty, high salinity tolerance, and resistance to cavitation under low NPSH conditions.
Fan Assembly Industrial axial fan with anti-corrosive coating and stainless shafting. Designed for static pressures of 300–800 Pa and airflow of 20,000–60,000 m³/h. Balancing ensures vibration limits per ISO 10816.
Mounting Options Skid-mounted (static), trailer-mounted (mobile), or tower-mounted as per site topography. Designed for seismic stability and wind load in open-pit mining conditions.
Maintenance Features Modular components for ease of nozzle replacement, fan motor servicing, and pump maintenance. Filters fitted with DP switches or auto-backwash option.